CANOGA PERKINS N525 Ethernet Termination Service Unit User Manual

Page 63

Advertising
background image

N525 Ethernet Termination Service Unit

3-45

3. At the Functional Configuration Menu, type the number for an item and press <Enter>.

Pressing <Space> cycles through the options. Press <Tab> to highlight the select Local or
Remote columns. Press <Enter> to select an option.

a. User Port Setting

Sets data rate and duplex option on the User Port. After typing [

1

] <Enter>, pressing

<Space> cycles through the Data Speed and Duplex options. Options are Interface
Module dependant.

b. Ext Port Setting

Sets data rate and duplex option on the User Port. After typing [

1

] <Enter>, pressing

<Space> cycles through the Data Speed and Duplex options. Options are Interface
Module dependant.

c. RMTF

Enables or Disables Remote Fault Forwarding (RMTF) when SBMC is enabled.
Enables or Disables Remote Fault Forwarding and Link Loss Echo (RMTF/LLE)
when SBMC disabled. Pressing <Space> cycles through the options. Options are
Disabled, Ext Port Enabled.

d. Link Loss Fwd

Enables or Disables Link Loss Forwarding (LLF). Pressing <Space> cycles through
the options. Options are Disabled, User – Ext, Ext – User, and Both Directions.

e. Flow Control

Enables or Disables flow control on the Remote port. Pressing <Space> cycles
through the options. Options are Disabled, Ext Port Enabled.

f. Maximum Frame Size: Sets maximum allowable Ethernet Frame size the N525 will

forward. Size range is 1518-10000.

g. Sideband Management

Enables or disables SideBand Management Channel (SMBC) communications with
a remote N525, L351 or L357. When enabled, pressing <ctrl> L verifications SMBC
connectivity with the remote unit.

h. Remote Configuration

Displays Functional Configuration of SBMC connected remote N525, L351 or L357.

4. To return to the Main Menu, press <Esc>.