CANOGA PERKINS 9145E Ethernet Network Interface Device Hardware User Manual
Page 14

9145E Ethernet Network Interface Device User’s Manual
Introduction
9145E Specifications
2
1.2 9145E Specifications
1.2.1 Physical Characteristics
Dimensions: 1.75" H x 8.25" W x 11.5" D (44.5 x 209.5 x 292 mm)
Weight: 6.5 lb (2.95 Kg)
1.2.2 Environmental Characteristics
Operating Temperature: 0° to 50° C
Operating Humidity: 90% (non-condensing)
1.2.3 Power Requirements
100 VAC to 240 VAC (auto-ranging), 50/60 Hz, 0.5 Amps
36 VDC to 72 VDC, 1.0 Amps
1.2.4 Regulatory Compliance
•
EN60825-1 (Laser Safety)
•
CE Mark
•
EMC Directive (EN55022 Class A, EN 55024, EN 61000-3-2/-3-3)
•
ETL, cETL & LVD (U.S. UL60950, CAN/CSA C22.2 No. 60950, EN/IEC 60950)
•
FCC Part 15B Class A (U.S.), ICES-003 (CAN), VCCI Class A (Japan), C-Tick
(AS/NZS 3548 - Australia)
•
NEBS Level 3 Certified & Tested
1.3 Mounting Requirements
The 9145E can be rack mounted (as a single unit or as two units side-by-side), wall mounted with
the front panel facing the floor, facing to the right, or facing to the left, or set on a desk, table or
shelf as a stand-alone unit. Reference Chapter 3, Installation, for 9145E installation procedures.
1.3.1 Rack Mounting
Canoga Perkins includes the mounting brackets required (see Figure 1-2) to allow the unit to be
mounted in a 19" or 23" rack.