6 setting alarm response actions – DVR systems DVR-HDE-960H-960H2 Series User Manual

Page 115

Advertising
background image



8.6 Setting Alarm Response Actions

Purpose:

The alarm response actions will be activated when an exception occurs, including Full Screen Monitoring,

Audible Warning, Notify Surveillance Center, and Send Email.

Full Screen Monitoring

When an alarm event (motion detection/tamper-proof/video loss detection) is triggered, the local monitor

(HDMI/VGA or BNC monitor) display in full screen the video image from the alarming channel configured

for full screen monitoring.

If alarms are triggered simultaneously in several channels, their full-screen images will be switched at an

interval of 10 seconds (default dwell time). A different dwell time can be set by going to Menu>

Configuration>Live View>Full Screen Monitoring Dwell Time.

Auto-switch will terminate once the alarm stops and you will be taken back to the Live View interface.

Note:

For motion detection alarm, you must select the channel(s) you want to make full screen monitoring

(Menu>Camera>Motion>Handling>Trigger Channel).

Audible Warning

Trigger an audible beep when an alarm is detected.

Notify Surveillance Center

Sends an exception or alarm signal to remote alarm host when an event occurs. The alarm host refers to the

PC installed with Remote Client.

Note:

The alarm signal will be transmitted automatically at detection mode when remote alarm host is

configured. Please refer to Chapter 9.2.6 for details of alarm host configuration.

Send Email

Send an email with alarm information to a user or users when an alarm event is detected.

Please refer to Chapter 9.2.10 for details of Email configuration.

Trigger Alarm Output

Note:

This feature is available for 960H2U

Trigger an alarm output when an alarm is triggered.

Steps:

1. Enter Alarm Output interface.

Menu> Configuration> Alarm> Alarm Output

models only.

Select an alarm output and set alarm name and dwell time.

Note:

If "Manually Clear" is selected in the dropdown list of Dwell Time, you can clear it only by going

to Menu> Manual> Alarm and clicking Clear All.





114