Connections

■Precautions when controlling the

AK-HC1500 from the AW-CB400

The AK-HC1500 supports the AK-HRP150 protocol and
AW-CB400 protocol, and It Is the AK-HRP150 protocol
which was set before the AK-HC1500 was shipped from the
factory.
When controlling the AK-HC1500 using the AW-CB400,
follow the steps below to change the protocol setting of
AK-HC1500 from AK-HRP150 to AW-CB400.

• When changing the protocol before installation

Refer to the operating instructions of the AK-HC1500,

and change the protocol.

• When changing the protocol after installation

® Proceed with the installation following the steps given

in the section entitled “Installation”.

@ Loosen the two top cover open/close bolts of the

camera housing, and open the top cover.

@ Set the power switch of the AC adapter to ON.

@ When the power of the AK-HC1500 has been

turned on, refer to the operating instructions of the
AK-HC1500, and change the protocol. (Change the

PROTOCOL setting on the SETTING menu to “4”.)

® Set the power switch of the AC adapter to OFF.

■Connections with AC adapter

• Disconnect the AC power cable which was already

attached.

• The cable used is purchased locally. Purchase a water­

proof cable designed to be used outdoors.

• Use a cable which has a high enough capacity (AC 220

to 240 V , 2 A o r more).

• Pass the cable through the rubber bushing for the AC

power input cable, and tighten it securely so that rain
water or drops of water will not seep inside.
[Thickness of compatible cable: 6.5 mm to 8.5 mm
diameter]

• Attach the power line (N, L) to the terminal block.

• Attach the ground line (FG) to the grounding screw ^).

28 (E)