Connections with ac adapter, Connections – Panasonic AW-PH650 User Manual
Page 29
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Connections
■Precautions when controlling the
AK-HC1500 from the AW-CB400
The AK-HC1500 supports the AK-HRP150 protocol and
AW-CB400 protocol, and It Is the AK-HRP150 protocol
which was set before the AK-HC1500 was shipped from the
factory.
When controlling the AK-HC1500 using the AW-CB400,
follow the steps below to change the protocol setting of
AK-HC1500 from AK-HRP150 to AW-CB400.
• When changing the protocol before installation
Refer to the operating instructions of the AK-HC1500,
and change the protocol.
• When changing the protocol after installation
® Proceed with the installation following the steps given
in the section entitled “Installation”.
@ Loosen the two top cover open/close bolts of the
camera housing, and open the top cover.
@ Set the power switch of the AC adapter to ON.
@ When the power of the AK-HC1500 has been
turned on, refer to the operating instructions of the
AK-HC1500, and change the protocol. (Change the
PROTOCOL setting on the SETTING menu to “4”.)
® Set the power switch of the AC adapter to OFF.
■Connections with AC adapter
• Disconnect the AC power cable which was already
attached.
• The cable used is purchased locally. Purchase a water
proof cable designed to be used outdoors.
• Use a cable which has a high enough capacity (AC 220
to 240 V , 2 A o r more).
• Pass the cable through the rubber bushing for the AC
power input cable, and tighten it securely so that rain
water or drops of water will not seep inside.
[Thickness of compatible cable: 6.5 mm to 8.5 mm
diameter]
• Attach the power line (N, L) to the terminal block.
• Attach the ground line (FG) to the grounding screw ^).
28 (E)