24

TROUBLESHOOTING GUIDES (continued)

PROBLEM:

KGL

Kettle Won't

Heat

Does red light

come on when unit

is first turned on?

Does red light go

off shortly after

unit is turned on?

Yes

Add water to

jacket of Kettle.

With the

potentiometer set

at 10, is 12 VDC at

the coil of the

relay?

No

Yes

Is 16 VAC

measured across

Pins 9 and 10 on

the controller?

No

Yes

Is 16 VAC at the

secondary side of

the transformer?

No

Replace

the on/off

switch (toggle

or rotary).

Yes

Is there Power to

the primary of the

transformer?

No

Replace the
transformer.

Yes

Supply power

to the kettle.

No

Does the relay pull

in?

Yes

Replace the

relay.

No

Is there power to

the blower?

Yes

With the high limit

temporarily

bypassed, is

power at the

blower?

No

Replace the

high limit.

Yes

Replace

the wire to
the blower.

No

Is there power to

the ignition

transformer?

Is there 24 VAC at

the secondary of

the ignition

transformer?

Is there 24 VAC to

the igniton

module?

Yes

Does the blower

turn?

Replace

blower.

No

Yes

Yes

Replace the

DC relay.

Replace the

ignition

transformer

Replace the air

switch.

No

Is there 120 VAC

to the igniter?

Yes

Replace

ignition

module.

No

Does the ignitor

glow?

Yes

Replace the

ignitor.

No

No

Does the gas

valve get 24 VAC

20 sec. after the

ignitor is

energized?

Yes

No

Does the gas

valve open?

Yes

Replace gas

valve

No

Yes

No