Gas kettle orifice replacement – Cleveland Range KGL-60-T User Manual

Page 34

Advertising
background image

31

GAS KETTLE
ORIFICE REPLACEMENT

Gas Orifice

Console Cover

"O" Ring

Spring

Plug

1. Remove Console Cover

2. Remove Plug and Spring

3. Remove Orifice

4. Replace with new Orifice and "O" ring

5. Replace Spring and Plug

6. Replace Console Cover

Kettles

BTU's per

Gas

Water

# of

Hour

Type

Column

Orifices

KGL-40,

140000

Natural Gas

3.5

1

KGL-40-T,

140000

Propane

3.5

1

KGL-60 to 100,
KGL-60-T to 80-T,

190000

Natural Gas

3.5

1

KGL-40-TSH,

190000

Propane

3.5

1

KGL-40-F to 60-F,
KGL-40-SH to 60-SH,

NOTE: Use thread sealant compatible with propane gas on
all threaded piping connections.

1.

Disconnect electrical connection.

2.

Shut off main gas supply and disconnect kettle from
supply line.

3.

Remove main kettle CONSOLE COVER.

4.

Remove PLUG and SPRING.

5.

Remove GAS ORIFICE and “O” RING.

6.

Replace first with new “O” RING and then GAS ORIFICE.

7.

Replace SPRING and PLUG.

8.

Replace main kettle CONSOLE COVER.

9.

Reconnect electrical supply.

Advertising
This manual is related to the following products: