Specification drawing, Dimensions, Water electric – Cleveland Range KGL-60-T User Manual

Page 7: Gas clearance

Advertising
background image

4

Specification Drawing -

Tilting, KGL-40-T, KGL-60-T, KGL-80-T

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Installation of backflow preventers, vacuum breakers and other specific codr requirements is the responsibility of the owner and installer.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.

1/2" dia. Soft
Copper
Tubing (each)

When ordered
with optional
faucet.

WATER

ELECTRIC

120V-1 Phase, 60 Hz, 10
amps

GAS

CLEARANCE

H

RIGHT = 0"
LEFT

= 0"

REAR = 3"

Allow 6" space minimum
from rear and sides when
located near combustible
walls. 12" recommended on
right side for service

NATURAL

PROPANE

Piping: 3/4" N.P.T.

Piping: 3/4" N.P.T.

Supply pressure:

Supply pressure:

4.00" W.C. minimum

4.00" W.C. minimum

14.00" W.C. maximum

14.00" W.C. maximum

Manufacturer must be notified if unit will be operated above 2,000 ft. altitude.

C

B.T.U. RATING

40 gal.

140,000

60 gal.
80 gal.

190,000

100 gal.

H C

DIMENSIONS

GALS./
LITERS

A

B

C

D

E

F

G

H

J

K

L

M

N

O

P

Q

S I.D.

40

IN

45 3/4 42 1/2

38

35

9

42 1/4

71

40 1/2 15 1/2 23 1/4

19

35 3/4 4 3/8

24

33

63

26

150

mm

1163

108

966

889

229

1074

1804

1029

394

591

483

909

112

610

839

1601

661

60

IN

49 3/8

46

41 1/2

37

11 3/4 47 1/4

75

43 3/4 15 1/4 24 1/2

22

39 3/8

6

28

37

68

29 1/2

225

mm

1255

1169

1055

940

299

1201

1905

1112

388

623

559

1001

153

712

940

1728

750

80

IN

53

49

44 1/2

39

14 3/4

51

78

44 3/4

14

25

25

43

7

30

40

72

33

300

mm

1347

1245

1131

991

375

1296

1982

1137

356

635

635

1093

178

762

1016

1829

839

J

K

C

H

N

O

M

L

Q

P

3"
(77 mm)
REF

S I.D.

C

B

A

G

HANDWHEEL REPLACED

BY SWITCH FOR

POWER TILT OPTION

H

F

E

D

2 1/4"
(57 mm)
REF

2 1/2"

(64 mm)

2 1/2"

(64 mm)

4 1/8"

(105 mm)

3" (77 mm)
MIN.
CLEARANCE

UNIT SHOWN WITH OPTIONAL 2" TANGENT DRAW-OFF VALVE,
SPRING ASSIST COVER AND HOT & COLD WATER FAUCET.

9/16"

14 mm

120º
TYP

1" (25 mm)

MAX. ADJUSTMENT

1 5/8" (42 mm) Ø

FLANGED FOOT DETAIL

7/16" (11 mm) Ø

3 HOLES ON

3 1/8" (80 mm) Ø

B.C.D.

4 7/8"

124 Ø mm

RECOMMENDED

FLOOR SLOPE

1" (26 mm) per 4' (1220 mm)

PIPE DRAIN RECOMMENDED
min. valve size plus 1" (26 mm)

4" (102 mm)

RECOMMENDED

VALVE OPENING

Advertising