TROUBLESHOOTING GUIDES (continued)

PROBLEM:

KGL

Kettle Not

Hot Enough

With kettle pot

empty and

temperature knob

set at 10, is the

temperature of the

surface of the pot

260 degrees?

Unit is

operating

properly

Yes

When unit is cold

(room temp) is the

pressure gauge in

the green?

No

Vent

the kettle per
instructions in

the manual.

No

When the unit is

calling for heat

(the green light is

on), is there flame

at the burner?

Yes

Is the resistance of

the thermister

100,000 ohms

+10% at room

temperature?

Yes

Replace the

thermister.

No

Is the

potentiometer

resistance 50,000

ohms at low and 0

ohms at high?

Yes

Replace

controller.

Yes

Replace the

potentiometer.

No

Does the kettle

heat at all?

Yes

See Problem:

Kettle won't

heat.

No

Is the blower

turning?

Replace the

high limit?

Is there voltage to

the blower?

No

Yes

No

Replace the

blower

No

Replace the air

switch

Yes

PROBLEM: KGL Kettle Has Delayed Ignition

Delayed Igniton

Is the gas

pressure to the

burner 3.5" W.C.?

Adjust or

replace the gas

Valve.

Does the ignior

glow evenly

Replace ignitor.

No

Yes

No

Does the gas

valve get 24 VAC

20 seconds after

the ignitor is

energized?

Replace the

ignition

module.

Is the blower

turning?

Replace blower

and air switch.

Replace burner

Yes

No

Yes

No

Yes