Specification drawing, Dimensions, Water electric – Cleveland Range KGL-60-T User Manual

Page 6: Gas clearance

Advertising
background image

3

Specification Drawing -

Stationary, KGL-40, KGL-60, KGL-80, KGL-100

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Installation of backflow preventers, vacuum breakers and other specific code requirements is the responsibility of the owner and installer.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.

1/2" dia. Soft

Copper Tubing
(each)

When ordered
with optional
faucet.

WATER

ELECTRIC

120V-1 Phase, 60 Hz, 10
amps

GAS

CLEARANCE

H

RIGHT = 3"
LEFT

= 3"

REAR = 3"

Allow 6" space minimum
from rear and sides when
located near combustible
walls. 12" recommended on
right side for service

NATURAL

PROPANE

Piping: 3/4" N.P.T.

Piping: 3/4" N.P.T.

Supply pressure:

Supply pressure:

4.00" W.C. minimum

4.00" W.C. minimum

14.00" W.C. maximum

14.00" W.C. maximum

Manufacturer must be notified if unit will be operated above 2,000 ft. altitude.

C

H C

B.T.U. RATING

40 gal.

140,000

60 gal.
80 gal.

190,000

100 gal.

DIMENSIONS

GALS./
LITERS

A

B

C

D

E

F

G

H

J

K

L

M

N

O

P

S

T I.D.

40

IN

35 1/8

37

32 1/4 40 1/2 9 1/4

16

71 1/2 9 9/16 17 3/4 25 15/16 10 3/8 18 5/8 26 7/8 28 1/2 4 5/8 24 1/2

26

150

mm

893

940

820

1029

235

407

1817

243

451

659

264

474

683

724

118

648

661

60

IN

38 1/4

39

34 1/4 43 1/2 8 3/4 14 1/4

75

8 15/16 19 1/8 29 5/16 10 3/8 18 5/8 27 7/8 30 1/4 5 1/4

27

29 1/2

225

mm

972

991

870

1105

223

362

1905

228

486

745

264

474

709

769

134

686

750

80

IN

41 5/8 42 3/8 35 1/2 45 1/2 8 3/4 15 1/2

79

9 1/4 20 3/4 32 1/4 10 3/8 18 5/8 29 5/8 31 1/2 6 5/8

29

33

300

mm

1058

1077

902

1156

223

394

2007

235

528

820

264

474

753

801

169

737

839

100

IN

44

43 1/2 36 1/2 47 1/2 8 3/4 15 1/2 83 1/2 9 1/8 21 7/8 34 5/8 10 3/8 18 5/8 31 1/4 32 1/2 7 1/2 30 1/2 35 1/2

375

mm

1118

1105

928

1207

22.3

394

2121

232

556

880

264

474

794

826

191

775

902

G

(COVER

OPEN)

3" (77 mm)
MINIMUM
CLEARANCE

F

3 (77 mm)

L

M

N

O

P

H

J

K

FLOOR DRAIN
12" (305 mm) WIDE x
12" (305 mm) LONG

UNIT SHOWN WITH OPTIONAL 2" TANGENT DRAW-OFF VALVE,
SPRING ASSIST COVER AND HOT & COLD WATER FAUCET.

75º

H C

E

D

A

S

C

4" (102 mm)

B

T

(I.D.)

RECOMMENDED

FLOOR SLOPE

1" (26 mm) per 4' (1220 mm)

PIPE DRAIN RECOMMENDED
min. valve size plus 1" (26 mm)

4" (102 mm)

RECOMMENDED

9/16"

14 mm

120º
TYP

1" (25 mm)

MAX. ADJUSTMENT

1 5/8" (42 mm) Ø

FLANGED FOOT DETAIL

7/16" (11 mm) Ø

3 HOLES ON

3 1/8" (80 mm) Ø

B.C.D.

4 7/8"

124 Ø mm

VALVE
OPENING