Specification drawing, Short series, kgl-40-sh, kgl-60-sh, Dimensions – Cleveland Range KGL-60-T User Manual

Page 8

Advertising
background image

5

Specification Drawing -

Short Series, KGL-40-SH, KGL-60-SH,

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Installation of backflow preventers, vacuum breakers and other specific code requirements is the responsibility of the owner and installer.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.

DIMENSIONS

MODEL NO

A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

S

T

KGL-40SH

IN

33

41.6

43.3 37.5

69

15.5

7.3

6.7

11

28

35.5

8.2

21.6

11.5

20.8 43.5

23

mm

838

1056 1099 953 1752

394

185

170

279

711

902

208

549

292

528 1105

584

KGL-60SH

IN

33.5

44

43.5 37.5

71

12.1

7.3

5.5

12.6 30.5 35.5

8.2

22.2

13.7

22.1 44.5

24.5

mm

850

1117 1104 953 1803

307

185

140

320

775

902

208

564

348

561 1130

622

GAS

ELECTRIC

WATER

CLEARANCE

NATURAL

PROPANE

BTU RATING

120V-1Phase, 60 Hz.

1/2" diameter

RIGHT = 0"

Piping 3/4" N.P.T.

Piping 3/4" N.P.T.

190,000

10 amps

Soft Copper

LEFT = 0"

Supply pressure

Supply pressure

Tubing each

REAR = 0"

4.00" W.C. Min.

11.00" W.C. Min.

When ordered

Allow 6" space min.

14.00" W.C. Max.

14.00" W.C. Max.

with optional

from rear and sides

faucet

When located near

combustible walls

9/16"

14 mm

120º

TYP

1" (25 mm)

MAX. ADJUSTMENT

1 5/8" (42 mm) Ø

FLANGED FOOT DETAIL

7/16" (11 mm) Ø

3 HOLES ON

3 1/8" (80 mm) Ø

B.C.D.

4 7/8"

124 Ø mm

RECOMMENDED

FLOOR SLOPE

1" (26 mm) per 4' (1220 mm)

PIPE DRAIN RECOMMENDED
min. valve size plus 1" (26 mm)

4" (102 mm)

RECOMMENDED

Advertising