TROUBLESHOOTING GUIDES (continued)

PROBLEM:

KGL Kettle

Gets Too

Hot

With the kettle
empty and the

temperature set at

10, is the surface

temp 260-265

degrees?

The

kettle is working

properly.

Yes

Does the kettle

continue to call for

heat (green light

stays on) when

the kettle reaches

260-265 degrees?

No

Is there supply

voltage to the coil

of the gas valve?

No

Replace the

gas valve.

No

Is there any DC

voltage to the coil

of the relay?

Replace the

Relay

Yes

Replace the

controller

Yes

No

Is the resistance of

;the thermister

100,000 ohms +

10% at room

temperature?

Yes

Replace the

thermister.

No

Is the resistance of

the potentiometer

50,000 ohms at

the low setting and

0 ohms at high?

Yes

Replace the

controller

Replace the

potentiometer

No

Yes

PROBLEM: Red Add Water LED Stays On

Does Red LED stay on
after adding the proper

amount of distilled

water and rust inhibitor?

Add the proper

amount of distilled

water and rust

inhibitor.

No

Is the red LED on

with probe

grounded?

Yes

Clean or

replace water

probe.

No

Does the red LED

stay on with a

jumper between

pins 5 and 7 on

the controller?

Yes

Replace the

wire harness in

the trunion.

No

Replace the

controller.

Yes