4. Control parameter and indication channels

4.1 Channel-overview

Legend:

x

Corresponding channel is available.

x*

Corresponding channel is available if the appropriate option
is activated.

Corresponding channel is only available if the option Energy
Production Measurement is activated (OHQM).

MEDT

The channel antifreeze content (MED%) is only shown
if the antifreeze is not water or Tyfocor LS / G-LS
(MEDT 0 or 3).
Adjustments concerning the antifreeze
content will only make sense if the antifreeze is used in the
solar circuit.

Corresponding channel is only available if the option Energy
Production Measurement is deactivated (OHQM).

Please note:

S3 and S4 are only indicated in case of sensors connected

Channnel

Arr

Specification

Page

1

2

3

4

5

6

7

8

9

COL

x

x

x

x

x

x

x

x

Temperature collector 1

15

COL 1

x

Temperature collector 1

15

TST

x

x

Temperature tank 1

15

TSTU

x

x

x

x

Temperature tank 1 below

15

TST1

x

x

x

Temperature tank 1 below

15

TSTO

x

x

x

x

x

Temperature tank 1 at the top

15

TST2

x

x

x

Temperature tank 2 below

15

TFSB

x

Temperature solid hot fuel boiler

15

TRET

x

Temperature heating circuit

15

COL2

x

Temperature collector 2

15

S3

x

Temperature sensor 3

15

TRF

Temperature return sensor

15

S4

x

x

Temperature sensor 4

15

hP

x

x

x

x

Operating hours relay 1

16

h P1

x

x

x

x

x

Operating hours relay 1

16

h P2

x

x

x

x

x

Operating hours relay 2

16

kWh

Heat quantity kWh

16

MWh

Heat quantity MWh

16

time

x

Time

15

Arr

1-9

System

12

DT O

x

x

x

x

x

x

Switch-on temperature diff

17

DT1O

x

x

x

Switch-on temperature diff 1

17

DT F

x

x

x

x

x

x

Switch-off temperature diff 1

17

DT1F

x

x

x

Switch-off temperature difference

17

S MX

x

x

x

x

x

x

Maximum temperature tank 1

17

S1 MX

x

x

x

Maximum temperature tank 1

17

DT2O

x

x

x

Switch-on temperature difference 2

17

DT2F

x

x

x

Switch-off temperature difference 2

17

S2MX

x

x

x

Maximum temperature tank 2

17

EM

x

x

x

x

x

x

x

x

emergency temperature collector 1

18

EM1

x

emergency temperature collector 1

18