4.1.1 Collector Temperatures

Shows the current collector temperature.

COL : collector temperature (1-collector-system)
COL1 : collector 1 temperature
COL2 : collector 2 temperature

COL, COL1, COL2:
Collector Temperature
display range: -40

→ +480°F

4.1.2 Tank Temperatures

Shows the current tank temperature.

TST : tank temperature (1-tank-system)
TSTL : tank temperature, lower
TSTU : tank temperature, upper
TST1 : tank 1 temperature
TST2 : tank 2 temperature

TST, TSTL, TSTU,
TST1, TST2:
Tank Temperatures
Display range: -40

→+480 °F

4.1.3 Sensor 3 and Sensor 4 Temperatures

Shows the current temperature of the corresponding addi-
tional sensor (without control function).

S3

: sensor 3 temperature

S4

: sensor 4 temperature

Please note:

S3 and S4 are only shown if the temperature sensors are
connected.

S3, S4:
S3, S4:
Sensor Temperatures
Display range: -40

→+480 °F

4.1.4 Other Temperatures

Shows the current temperature of the corresponding
sensor.

TFSB : solid fuel boiler temperature
TRET : heating reverse raising temperature
TRF : return flow temperature

TFSB, TRET, TRF:
O t h e r M e a s u r e d
Temperatures
Display range: -40

→+480 °F

4.1.5 Time

This channel stores and displays the current time in 24
hour format. To change the stored time, press the key 3 for
2 seconds. This causes the

icon to blink and the hour

may be adjusted using keys 1 and 2. To adjust the minutes
press key 3 again. The

icon continues to blink, but keys

1 and 2 now cause the minutes to change. Pressing key 3
again causes the displayed value to be stored.