Som 7 si, Symptom possible cause and remedies list, Troublesooting tips – STIEBEL ELTRON SOM 7 SI User Manual

Page 25: F ω °f ω

Advertising
background image

© 08042 som_7_si.monen.ind

d

25

|

SOM 7 SI

5. Troublesooting Tips

If a malfunction occurs, it will be indicated on the display of
the controller:

Operating control lamp

Warning symbol

1

2

S1

S2

S3

3

4

5

6

Temp. Sensor Pt1000

L

N

R1

N

R2

N

20

19

18

17

16

15

S4

7

8

14

13

12

DE - 45527 Hattingen

DeltaSol BS Plus

2 (1) A 115
2

V~

(1) A 115 V~

R1
R2

T4A

115 V~

CU 72060171 01

UL 60730-1A:2002

CSA E60730.1:2002

VBus

9 10

°F

Ω

°F

Ω

14

961

131

1213

23

980

140

1232

32

1000

149

1252

41

1019

158

1271

50

1039

167

1290

59

1058

176

1309

68

1078

185

1328

77

1097

194

1347

86

1117

203

1366

95

1136

212

1385

104

1155

221

1404

113

1175

230

1423

122

1194

239

1442

Resistance values of the

Pt1000-sensors

Symptom

Possible Cause and Remedies List

Operating control lamp flashes red. The

symbol is displayed and the

symbol is flashing.

The indication channel of the relevent sensor
displays 888.8 instead of the temperature.

SOM unit is sensing an open circuit condition.

Measure the resistance between the two terminals to which

1.

the relevent sensor is attached. If it measures infinite resis-
tance continue to step 2. If it measures a resistance within
range of the above chart, call for service.
Disconnect the sensor wire from the terminals and measure

2.

the resistance between the two wires. If it still measures infi-
nite resistance continue to step 3. If it measures a resistance
within range of the above chart, there is a problem with the
connection from the sensor wire to the terminal.
This problem lies either with the sensor or the wire/connec-

3.

tions. In order to determine whether the problem lies with
the sensor itself, the sensor must be disconnected from any
extension wire and its resistance must be measured. If, when
the sensor is disconnected, the resistance is measured to be
within the values of the resistance chart the problem is with
the extension wire/connections.