Maintenance, Fault diagnostics – 360 Systems 1200HD-EX User Manual

Page 114

Advertising
background image

MAXX-1200 Owner’s Manual

Page 113


Maintenance

Fault Diagnostics

Front Panel Indicators

The five LED indicators on the front panel are used to diagnose server fault conditions. The
meaning of each indicator is noted in the following table. During normal operation, all five
indicators will be on.

GENLOCK

OFF indicates that the Genlock
setting in the System menu is
“Internal”

FLASHING indicates that Genlock is
selected in the System menu, but
there is no signal, or an invalid signal
at the

GENLOCK input connector.

Check the Genlock setting in the On-
Screen System menu.

Check the Genlock cable connections
or signal.

POWER

FLASHING indicates that there is a
fault in the system power supply.

Shut down the server and contact 360
Systems Customer Support for further
hardware diagnosis.

FANS

FLASHING indicates that an internal
chassis or CPU fan is running slow or
stopped.

Check the chassis fan operation.
Replace if necessary. Do not run the
server without a working fan.

DRIVES

FLASHING indicates that there is a
fault in the system RAID array.

Check the RAID array status using
the utility under
Start > Raid Status.

SYSTEM

FLASHING indicates that the CPU or
other temperature or voltage reading
is not within manufacturer’s
specification.

Shut down the server and contact 360
Systems Customer Support for further
hardware diagnosis.

Repairs should be performed only by
qualified electronics technicians.

Advertising