Audio level calibration, Calibration procedure – 360 Systems 1200HD-EX User Manual

Page 117

Advertising
background image

Page 116

MAXX-1200 Owner’s Manual

Audio Level Calibration

The input and output gain of the analog audio circuits is factory calibrated to a +4 dBu
standard. Each circuit includes a trimmer with a range of approximately ±1.5 dB. The
following procedures may be used to calibrate these to unity gain. Each trimmer is located
above the XLR connector with which it is associated.

Calibration Procedure

This procedure assumes that the technician is familiar with test procedures employing the
Audio Precision® test equipment or its equivalent.
1. Play the test clip titled zTONE present on the server disk. This is a two-channel clip

recorded at a level equivalent to a +4 dBu output level.

2. While observing the output level of audio Channel 1 Left, adjust trimmer RV4 until a level

of exactly +4.0 dBu is obtained.

3. Repeat this procedure for audio Channel 1 Right, while adjusting trimmer RV3, and also for

each subsequent audio channel using its associated trim pot.

After calibrating the gain settings for all analog audio outputs as in steps 1 through 3 above,
calibrate the server’s input gain as follows:
4. Using the graphic user interface, place server Channel 1 in the E-E mode, so an input signal

will appear at its output.

5. While observing the output level of audio Channel 1-L, apply a 1 KHz sine wave from the

audio generator to audio Input 1-L.*

6. Adjust input trimmer RV2 until a level of exactly +4.0 dBu is obtained at the output of

Channel 1L.

7. Repeat this procedure for audio Input 1-R, making the gain adjustment with input trimmer

RV1.

The preceding steps establish a gain of unity through the server.

* In the absence of a generator, use the calibrated outputs of Channel 2 playing zTONE to

feed the inputs.

Advertising
This manual is related to the following products: