68 •

Interface Wiring

Remote Control

This connection is dedicated to a 360 Systems RC-320 Remote Control with a D-SERIAL-320 Remote
Control interface cable. This port communicates with the remote control and also provides power to it.

PIN

SIGNAL

1

GND

2

+5 VOLTS (Not normally used)

3

GND

4

TX + (DigiCart Transmitter, wire to RX+)

5

TX – (DigiCart Transmitter, wire to RX-)

6

Remote Present RTN

7

+12V

8

GND

9

N/C

10

N/C

11

RX + (DigiCart Receiver, wire to TX+)

12

RX - (DigiCart Receiver, wire to TX-)

13

Remote Present signal

14

+12V

15

GND

Remote Bus

This connection is dedicated to 360 Systems RC-210/220 Remote Controls and/or the RC-210/220/320
Control Bus daisy-chain.

PIN

SIGNAL

1

GND

2

+5 VOLTS (Not normally used)

3

GND

4

TX + (DigiCart Transmitter, wire to RX+)

5

TX – (DigiCart Transmitter, wire to RX-)

6

HSK OUT (Not normally used)

7

HSK IN (Not normally used)

8

RX + (DigiCart Receiver, wire to TX+)

9

RX - (DigiCart Receiver, wire to TX-)