Allow adequate ventilation when mounting the AV‑M8 in any enclosed space

to avoid damage to the product caused by overheating.

To add the mounting flanges to the AV-M8, align the holes in the flange to

those in the side of the AV-M8.

Rack Mounting

To rack mount the AV‑M8 Mic Input Module, attach the rack‑mount ears

using the supplied Phillips screws. The rack ears can be attached to the front

or rear of the AV‑M8. Next, position the AV‑M8 in the equipment rack at the

desired location. Use standard rack‑mounting screws (10‑32 size) to attach

the AV‑M8 to your rack hardware. Tighten all four screws firmly, but avoid

overtightening.

Aviom suggests the use of non‑metallic washers between the rack‑mounting

screws and the device’s finished surface to avoid marring the painted finish

on your Aviom products.

Always allow adequate ventilation for devices mounted in equipment racks.

Avoid placing your AV‑M8 directly above or below other rack‑mounted

devices that produce high levels of heat, such as power amps.