Allow adequate ventilation when mounting the AV‑M8 in any enclosed space
to avoid damage to the product caused by overheating.
To add the mounting flanges to the AV-M8, align the holes in the flange to
those in the side of the AV-M8.
Rack Mounting
To rack mount the AV‑M8 Mic Input Module, attach the rack‑mount ears
using the supplied Phillips screws. The rack ears can be attached to the front
or rear of the AV‑M8. Next, position the AV‑M8 in the equipment rack at the
desired location. Use standard rack‑mounting screws (10‑32 size) to attach
the AV‑M8 to your rack hardware. Tighten all four screws firmly, but avoid
overtightening.
Aviom suggests the use of non‑metallic washers between the rack‑mounting
screws and the device’s finished surface to avoid marring the painted finish
on your Aviom products.
Always allow adequate ventilation for devices mounted in equipment racks.
Avoid placing your AV‑M8 directly above or below other rack‑mounted
devices that produce high levels of heat, such as power amps.