Adat® digital i/o, Clock source, Adat – Aviom AV-M8 User Manual

Page 27: Digital i/o, Av-m8

Advertising
background image

19

Av-M8 M

ic

i

nput

M

odule

u

ser

G

uide

POWER

ON

EXPANSION

OUT

IN

AV-M8

STEREO LINK

CLOCK SOURCE

INTERNAL

ADAT

CH 9-16

250VAC-F4AL

OUT

ADAT

®

When the Power LED is lit, the AV-M8 is outputting A-Net.

ADAT

®

Digital I/O

The AV‑M8 includes digital I/O designed to allow two AV‑M8 modules to be

linked together, creating a single 16‑channel A‑Net stream. ADAT® Lightpipe®

digital connections are used, allowing simple plug‑and‑play operation when

creating a 16‑channel system.

POWER

ON

EXPANSION

OUT

IN

AV-M8

STEREO LINK

CLOCK SOURCE

INTERNAL

ADAT

CH 9-16

250VAC-F4AL

OUT

ADAT

®

ADAT Clock Source (left) and digital I/O connections (right)

Two Lightpipe connections are provided, In and Out, as well as a clock source

switch that allows the Pro16 network clock source to be set to internal clock

or to the clock imbedded within the ADAT digital signal.

Cables for the ADAT I/O use standard, readily‑available Toslink® connections.

Lightpipe cables of up to three meters in length can be used.

Clock Source

The Clock Source switch selects either the internal A‑Net clock or the clock

imbedded within the ADAT digital signal as the network clock. When only

one AV‑M8 is used, the clock source should be set to Internal. When using two

AV‑M8 modules to create a 16‑channel A‑Net stream, the AV‑M8 receiving

ADAT data should be set to use the ADAT clock.

Advertising