Aviom AV-M8 User Manual
Page 31
23
Av-M8 M
ic
i
nput
M
odule
u
ser
G
uide
To connect an unbalanced line‑level device to the input channels of the
AV‑M8 using two‑conductor shielded cable:
Strip the insulating jacket of the cable back about .75 inch
1.
(18 mm) to reveal the individual hot, cold, and ground
wires within.
Remove a small amount of each individual wire’s insulation
2.
(approximately .25 inch, 6 mm).
Apply a small amount of solder to each bare wire.
3.
On the Euroblock plug, use a small screwdriver to loosen
4.
and open the sockets that will receive the individual wires.
Insert the audio cable’s hot (+) wire into the matching
5.
socket on the Euroblock plug.
Insert the audio cable’s cold (‑) wire into the matching
6.
socket on the Euroblock plug.
Insert the audio cable’s ground wire into the matching
7.
socket on the Euroblock plug.
Tighten the screws on the wire sockets to secure the
8.
individual wires.
Plug the completed Euroblock plug into the desired input
9.
channel.
At the other end of the cable, connect the hot (+) wire to
10.
the unbalanced source’s hot connector.
Connect the cold (‑) and ground wire to the unbalanced
11.
source’s ground connector.
Plug the completed Euroblock connector into the channel’s input jack.