Parameter setting mode, Changing engineering units – Checkline FGS-220VC User Manual

Page 26

Advertising
background image

- 21 -

Force limit

The stand controls to give the force less than the "Force limit".
If the force limit is detected, the stand will stop immediately. Then the stand executes the next step.














Detect object

The parameter is the threshold force level for detecting the object.
When the setting force of "Detect object" parameter is detected, the stand will stop immediately. Next
the stand moves to opposite direction until detecting "Zero force".
The recommended "Detect object" that the user should program into the stand is more than 0.2% of
the full scale of the mounted force gauge, i.e., if the programmer is using a 200lb force gauge, the
programmed "Detect object" should be 0.4lb (200lb x 0.2%).

5.5. Parameter setting mode

The relations function is set to the entire stand.

Contents

The parameters are shown in the below table.

Items

Description

Range

Sign of Push direction

The sign at the position of the direction of
Push is set.
If it sets "-" and the stand moves to Push, the
display of position is decrement.

[space], -

Acceleration

The acceleration of the motor of the stand is
set.
The acceleration is the slope or rate of
increase in speed from the non-motion
starting point to the set programmed speed.
If the parameter is set at a maximum of 100,
the motor will accelerate quickly

1 to 100 (step 1)

Volume of buzzer

The volume of the buzzer is adjusted.

OFF, Low, Middle, High


Upper limit

Lower limit

Start point

Detect point

Standard point

Point 1

Point 4

Point 5

Point 3

Point 2

Example

Point 4

Point 5

Detect

the force limit

Advertising