6 using the device, 1 conducting a grinding operation, 1 parameters – FRITSCH PULVERISETTE 0 User Manual

Page 22: 2 fitting and clamping the mortar, 1 parameters 6.1.2 fitting and clamping the mortar, 6using the device

Advertising
background image

6

Using the device

6.1 Conducting a grinding operation

6.1.1 Parameters

Grinding duration

10 ... 30 min (average)

Amplitude

1 ... 2 mm (max.)

Feed quantity

Max. 10 ml (particle feed size ≤ 5

mm)

6.1.2 Fitting and clamping the mortar

1.

Move the clamping lever on the belt clamping device downwards

and insert the toothed belt through the holder from the inside to

the outside.

2.

Place the mortar and the ball on the vibratory plate. The mortar

must be positioned in the round gap of the vibratory plate without

being wedged.

3.

Unscrew the knurled knob on the toothed belt as far as possible.

4.

Pour in the grinding stock.

5.

Put on the clamping lid.

6.

Attach the knurled knob to the lid

7.

Lightly pull the toothed belt tight and move it upwards until its

teeth interlock with the teeth of the belt clamping device.

8.

Move the clamping lever upwards.

Make sure that the teeth of the toothed belt interlock

with the teeth of the belt clamping device!

9.

By turning the knurled knobs to the right, tighten the mortar

evenly until the toothed belts are tightly clamped!

If the two toothed belts are not evenly clamped, it is

possible that the grinding stock will escape from the

mortar.

Select an amplitude for grinding at which the ball vibrates. The best

grinding results can be achieved at a medium amplitude (1 mm to max. 2

mm), as the impact frequency of the grinding ball is then highest.

Using the device

- 22 -

Advertising