Maintenance – FRITSCH PULVERISETTE 13 premium line User Manual

Page 42

Advertising
background image

9.

The funnel (4) needs to be removed so that the fixed grinding disk

(5) can be dismantled.

10.

For this, remove the 3 marked cylinder screws.

11.

Take the funnel off towards the front by tugging it.

ð The fastening screws of the fixed grinding disk become visible.

12.

CAUTION!
Crushing hazard when exchanging the grinding disks.

Make sure that the grinding disk does not fall on the

floor.

Loosen the 2x M30 fastening screws using the locking handle (K).

Hold the grinding disk firm. Remove the hexagon screws and take

off the grinding disk.

13.

Now take the movable replacement grinding disk (6) and secure it

by hand with the 2 hexagon screws. Then tighten with the spanner

(R).

14.

Remove the locking spanner (B) and close the grinding chamber

manually.

15.

By using the setting screw to adjust the gap (7), enlarge the gap

with a maximum of 3 turns to the left.

Maintenance

- 42 -

Advertising