Malfunction

Possible cause

Rectify fault

Grinding disks not installed parallel

Dismantle grinding disks, clean

holder and install again (See

Ä

Chapter 6 ‘Using the device’

on page 23)

Grinding stock escapes

Grinding chamber and grinding stock

container seals are soiled or defec-

tive

Clean or replace seals

Collecting container overflow (max. 2

L)

Take out the container and clean the

interior

Error message, grinding stock con-

tainer

Grinding stock container not

accepted

Slide the container in centrally

Soiling of the container guide

Cleaning

After STOP, no release of the

grinding stock container

Lock release mechanism of the

grinding stock container is defective

Unlock with the emergency release

on the inside of the device, see

Ä

Chapter 2.8.2 ‘Protection against

restart’ on page 15. Contact Fritsch

Automatic gap adjustment not pos-

sible

Control panel defective

Replace control panel

Gap adjustment defective

Contact Fritsch
Temporary solution of the problem

with the setting screw (7) on the

right, bottom front side. Set the pre-

cise gap width manually.

Disks are stuck

Turn loose with the help of the set-

ting screw (7). Readjust the zero

point.

Error message

Gap width, grinding chamber,

grinding stock container

Press STOP button

Repairs

- 47 -