Holtgreven USED OCS-B 40,000 lb (x 20) User Manual

Page 18

Advertising
background image

OCS User Guide

Page 15 of 24

Resolution Switch 

Action 

To switch scale’s resolution, press 

  and 

  on remote controller in turn.   

Function 

The screen flashes the resolution to change in descending order, like 5kg, 2kg, 1kg 

(available optional resolution ranges from 0.01 kg or lb to 50 kg or lb, depending on scale’s 

capacity). After R

ESOLUTION 

S

WITCH

, new resolution takes effect. 

To balance between accuracy and measurement speed in high resolution mode, 

A

NTI

‐M

OTION 

L

EVEL

 can be changed to fit your measurement application. 

To learn how to set Anti‐Motion Level, please refer to the Anti‐Motion Level in 6 

Advanced Operation section. 

Condition 

;

The scale must not be in H

OLD

 mode. Otherwise, error message 

  will keep 

flashing.   

 

Battery Check 

B

ATTERY

C

HECK

R

ESOLUTION

S

WITCH

NOTICE:

R

ESOLUTION

S

WITCHING

will change the apparent overloading range of

the scale. For example, if the resolution of a 3000kg scale is switched to

0.5kg, it will overload at a new weight of 3004.5kg (3000 + 9*0.5), while by

default, it overloads at a weight of 3009kg (3000 + 9*1).

NOTICE:

High resolution offers better accuracy at the cost of longer measuring

time and stricter requirement of load’s stability. Designed to meet the OIML

R76’s directive, this scale has the best (default) performance at 2000 to

3000 division.

NOTICE:

The default resolution will be restored next time when the scale is

powered on or enter System Setup Mode (no matter the setting is changed

or not). To save the changes in resolution for later, use S

YSTEM

S

ETUP

function, rather than R

ESOLUTION

S

WITCHING

.

NOTICE:

Setting or changing TARE has no effect on the ZERO setting.

Advertising