Holtgreven USED OCS-B 40,000 lb (x 20) User Manual

Page 19

Advertising
background image

OCS User Guide

Page 16 of 24

Action 

To check scale’s battery power, press 

  and 

  on remote controller in turn.   

Function 

System checks the battery, and feedbacks with battery’s left charge.   

The screen flashes the battery charge in voltage, like the below 6.42V. 

Please flip to 7 Battery section for more information about battery. 

Condition 

;

The scale must not be in H

OLD

 mode. Otherwise, error message 

  will keep 

flashing.   

System Setup 

Action 

To enter S

YSTEM 

S

ETUP 

M

ODE

, press 2ND and HOLD button on scale or 

  and 

  on 

remote controller in turn. 

To input digits, press ZERO and TARE button on scale or 

  and 

  on remote 

controller. 

To confirm the password or input value, press HOLD button on scale or 

  on remote 

controller. 

To save and exit S

YSTEM 

S

ETUP 

M

ODE

, press 2ND button on scale for 

  on remote 

controller. 

To exit S

YSTEM 

S

ETUP 

M

ODE

 without saving, press ON/OFF button on scale or 

  on 

remote controller. 

To learn how to input digits or change the option, please refer to 5 User Input section. 

Function 

In S

YSTEM 

S

ETUP 

M

ODE

, user can change the scale’s system function to their desired state, 

like higher resolution, automatic power‐off delay, idle delay, the screen’s brightness, display 
frequency, and anti‐motion level etc.   

The screen displays the welcome message as below. 

Condition 

;

The scale must not be in H

OLD

 mode. Otherwise, error message 

  will keep 

flashing.   

Resolution 

S

YSTEM

S

ETUP

R

ESOLUTION

Advertising