9. Troubleshooting

 
Symptom 

Possible Cause 

Suggested Solution 

Blank display when Power On/Off 

button is depressed 

Discharged battery 

Recharge the battery 

Defective battery 

Replace the battery 

Corroded battery 

Clean connections 

Power button not properly 

depressed 

Press Power On/Off firmly and hold until 

power turns on. 

Display flashed at low brightness 

Discharged battery 

Recharge the battery 

No action taken after Zero / Tare / Hold 
/ 2nd button pressed 

Defective button 

Clean button 

Display reading not stable 

The scale is in great motion 

Wait until the scale is stable 

Filter (Anti‐Motion) set too 

low 

Change filter (Anti‐Motion) setting 

The scale is damped 

Dry the scale 

Dust on PCB boards 

Clean PCB board 

Reading not zero without load 

System power is not stable 

Give the scale longer warm‐up time 

The load‐cell stressed too 

much and too long 

Hang the scale in storage 

Large error in weight reading 

The scale is not zeroed before 
applying load 

Zero the scale before loading 

Require re‐calibration 

Re‐calibrate the scale 

lb/kg unit in wrong selection 

Set correct unit 

Battery can not be recharged 

Defective battery 

Replace the battery 

Defective charging plug 

Replace the charging plug 

Short remote controlling distance 

Remote controller batteries are 

dead 

Replace remote controller batteries 

Advertising