OCS User Guide

Page 5 of 24

;

The scale must be stable. Otherwise, error message 

  will flash. 

;

Current weight reading must be greater than 0 (or 0.0 or 0.00, depending on the resolution). 

Otherwise, error message 

  will flash. 

;

Current weight reading must be fewer than 100% scale’s M

AXIMUM 

C

APACITY

. Otherwise, 

error message 

  will flash. 

;

The scale must be in gross mode. Otherwise, this action will be recognized as T

ARE 

O

UT

. 

Tare Out 

Action 

To T

ARE 

O

UT 

the tare weight out of scale, press TARE button on scale or 

  on remote 

controller (when the scale is in N

ET 

M

ODE

).   

Function 

The scale clears the tare weight, returns to gross mode, and displays all subsequent 

readings in G

ROSS 

M

ODE

.   

The TARE indicator 

  lights off.   

The weight reading is added with tare weight. 

Condition 

;

The scale must not be in H

OLD

 mode. Otherwise, error message 

  will keep 

flashing.   

;

The scale must be in N

ET 

M

ODE

. Otherwise, this action will be recognized as T

ARE

 I

N

Hold 

Action 

To H

OLD

 the weight reading, press HOLD button on scale or 

  on remote controller.   

Or 

To unlock current reading, press HOLD button on scale or 

  on remote controller again. 

Function 

The HOLD indicator 

  lights on.   

All subsequent readings are locked to current reading.   

Or 

The HOLD indicator 

  lights off.   

The weight reading is unlocked. 

Condition 

;

To H

OLD

 the scale, it must be stable. Otherwise, error message 

  will flash. 

NOTICE:

Setting or changing TARE has no effect on the ZERO setting.

NOTICE:

Tareing will reduce the apparent overloading range of the scale.

For example, if a 1000kg container is tared and the scale maximum

capacity is 5000kg, the scale will overload at a new weight of 4009kg (5000

– 1000 + additional 9 divisions).

H

OLD

T

ARE

O

UT

Advertising