The formula to compare – A&D Weighing SJ-30KWP User Manual
Page 14
![background image](/manuals/659045/14/background.png)
12
6: To compare stable data which are
≥ +5d.
d = minimum display in kg (Refer to “13. SPECIFICATIONS”.)
In the counting mode, “d” is equal to the minimum weight display of kg mode.
8.1. The formula to compare
Comparison is performed using the formula listed below and the results are output.
Five-level comparator mode
Results
Comparison formula
LED display
LOLO Displayed
value
< LOLO limit, or “
-e
”
( Red LED on)
LO LOLO
limit
≤ Displayed value < LO limit
( Yellow LED on)
OK LO
limit
≤ Displayed value ≤ HI limit
( Green LED on)
HI
HI limit < Displayed value ≤ HIHI limit
( Yellow LED on)
HIHI
HIHI limit < Displayed value, or “
e
”
( Red LED on)
Three-level comparator mode
Results
Comparison formula
LED display
LO
Displayed value < LO limit, or “
-e
”
( Red LED on)
OK LO
limit
≤ Displayed value ≤ HI limit
( Green LED on)
HI
HI limit < Displayed value, or “
e
”
( Red LED on)