Ae rco, Appendix g, Piping diagrams – AERCO BMK 2.0 LN Dual Fuel Nov 2010 User Manual

Page 113: Leg e nd

Advertising
background image

APPENDIX G

G-3

PIPING DIAGRAMS

* C

O

N

D

EN

SAT

E

D

R

AIN

T

R

AP

1-

1/2"

NPT

DR

A

IN CO

N

N.

BAC

KF

LOW PR

EVE

N

T

ER

D

IA

P

H

R

AGM T

YPE

EXPAN

SION

T

A

N

K

LINE

SIZ

E

B

Y

PASS

SU

PPLY

WAT

E

R

H

EAT

IN

G

SYST

E

M

S

U

PPLY

PR

ESSU

R

E

RE

DUC

ING

F

ILL

V

A

LVE

P&T

SYST

EM

PU

M

P

CH

E

CK

VAL

V

E

(T

Y

P

.)

A

U

TO

M

A

TI

C

AIR

VEN

T

AIR

SEPAR

A

T

OR

P&

T

N

AT

. GAS SU

PP

L

Y

H

EAT

IN

G SYST

EM

R

ET

U

R

N

* 2

"

M

A

N

U

AL

SH

U

T

O

F

F

VA

L

V

E

P&

T

RE

L

IE

F

V

AL

V

E (

T

YP.)

P&T

P&T

5

) TH

IS

IS A TYP

ICA

L I

N

ST

AL

LA

TI

ON

DR

AW

IN

G.

L

O

CA

L CO

DE

S AN

D

A

UT

HOR

IT

IE

S

S

HOU

LD

BE C

O

NS

UL

TE

D.

FI

T

T

INGS

T

O

P

RE

VEN

T I

N

TE

RF

ERE

NC

E

W

ITH

RE

MO

VA

L OF

B

O

IL

ER

PA

NE

LS A

ND COV

ER

S.

A

L

L

P

IPI

NG

AND

E

L

E

CT

RI

C

CO

NNE

CT

IO

N

S (

SE

RVI

CE

SWI

T

C

HES

, COND

UI

T

BOX

ES

) SH

OUL

D L

IKE

WI

SE

B

E 6"

AWA

Y FR

OM

S

ID

E PA

NE

LS.

4) L

O

C

A

TE

W

A

TE

R

IN

L

E

T

A

N

D

O

U

TL

E

T

F

ITT

IN

G

S

(

i.e

. U

N

IO

N

S

, E

L

B

O

W

S

, E

T

C

.)

A

M

IN

IM

U

M

O

F

6'

'

FR

O

M

B

O

IL

E

R

T

O

A

C

O

NV

ENI

E

NT

FLO

O

R

DR

AI

N.

RE

LI

EF

V

AL

VE

SH

OUL

D B

E PI

PE

D VE

RTI

CAL

LY T

O

A HE

IG

HT

1

8

'' AB

OV

E F

L

OO

R.

1)

F

O

R A

CTU

AL

SI

ZE

S

A

ND

LOC

ATI

ONS

OF

PI

PI

NG

AND

OT

HE

R C

O

NN

EC

TI

ONS

T

O

T

HE BO

IL

ER,

S

EE DI

M

ENS

IO

NAL

DR

AWI

NG

(AP

-A-

87

4)

.

3

) AL

L (*

) I

T

EMS

ARE

I

N

C

L

U

D

E

D

SE

PAR

AT

EL

Y I

N

SHI

P

MEN

T

F

R

OM FA

CT

ORY

.

2)

SH

EL

L DRA

IN VA

LV

E AN

D

C

O

N

DEN

SAT

E D

RA

IN TR

AP

SH

OUL

D BE

AR

RA

NGE

D T

O

PER

MI

T T

HE

F

L

U

IDS

TO

D

RAI

N

FRE

ELY

,

B

Y GR

AVI

T

Y,

NO

T

ES

:

DA

T

E

DA

T

E

AE

RCO

BE

NC

HM

ARK

2

.0

MI

L

. BT

U LO

W NOx

DUA

L FU

EL

GAS

FI

RED

MU

LTI

P

LE B

O

IL

ER

S

W

IT

H ZE

RO

SI

DE CL

EA

RAN

CE

I

N

ST

ALL

AT

ION

A

PPD

.

DWN

.B

Y

SC

AL

E

HM

NT

S

N

O

R

T

H

VALE,

N

J

0764

7

IN

TER

N

A

TI

O

N

A

L,

IN

C

.

0714

1

0

S

D

-A

-819

T

EM

P

ER

AT

UR

E

GA

U

G

E

P&

T

PR

ESS

UR

E &

IS

O

L

A

T

IO

N

V

A

LV

E

UNI

O

N

Y

ST

RA

IN

ER

LEG

E

ND

BA

LAN

C

IN

G

V

A

LV

E

RE

V

A

6)

WHE

N

A

VAI

LA

BL

E GAS

P

R

E

SSU

RE

I

S

G

R

E

ATE

R TH

AN

2

.0

PSI

G,

A

L

O

C

K-U

P S

T

YL

E R

EG

U

LAT

O

R

MUST

B

E I

N

S

T

A

L

L

ED

DOW

NS

T

RE

AM

OF

THE

2"

M

ANU

AL

SHU

T

O

FF V

ALV

E T

O

BR

ING

TH

E GAS

PRE

SSU

RE

DOWN

TO

2

.0

P

SI

G

.

A

T

MA

X

IMUM B

T

U/

HR I

N

P

UT,

M

A

IN

T

A

IN

M

IN

IM

U

M

GAS

PR

ESS

U

R

E

AT

8.

5"

W

.C

.(F

M

GA

S

T

R

A

IN

);

8.

5

" W

.C

. (I

R

I).

M

AX

. G

A

S

PR

ES

S

U

R

E

=

2

.0

PS

IG

. (

SEE

N

O

T

E

6)

D

R

IP T

R

AP

A

T

MA

X

IMUM B

T

U/

HR I

NP

UT,

M

A

IN

T

A

IN

M

IN

IM

U

M

P

R

O

PAN

E

PR

ES

SU

R

E

AT

4

.0

" W.

C.

(FM G

A

S

TRA

IN);

4

.2

"

W

.C.

(I

RI

).

M

A

X.

G

AS

PR

ES

S

U

R

E

=

2.0

P

S

IG.

(S

EE N

O

T

E

6

)

PR

O

P

A

N

E

S

U

PPLY

Advertising