Installation Instructions

5B MAKE ELECTRICAL CONNECTIONS

Place the unit on a platform or table even with the cutout opening. The platform must support 200 lbs. (91 kg).

Connect the flexible conduit to the electricaljunction box os follows:

THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION

NOTE: If residence leads or ground are aluminum conductors, see WARNING in section 5A, Electrical
Requirements.

When connecting to a three-conductor branch circuit, if local codes permit:

1. Connect the bare oven ground conductor with the

crimped neutral (white) lead to the branch circuit

neutral (white or gray in color), using wire nuts.

2. Connect the oven red lead to the branch circuit red

lead, and the oven black lead to the branch circuit
black lead in accordance with local codes, using

wire nuts.

Black

Range conduit

snaps into box

3. Install proper strain relief clamp.

4. Installjunction box cover.

Red

Ground and
neutral wires
(white)

Alternate

knockout

Neutral bore wire

connection

FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION

NOTE: If residence leads or ground are aluminum conductors, see WARNING in section 5A, Electrical
Requirements.

When connecting to a four-conductor branch circuit, if local codes permit:

1. Cut the neutral (white) lead from the clamp. Re-strip

the neutral (white) lead to expose the proper length
of conductor.

Black

2. Attach the appliance grounding lead (green or bare

copper) in accordance with local codes.

3. Connect the oven neutral (white) lead to the branch

circuit neutral (white or gray) in accordance with

local codes, using a wire nut.

4. Connect the oven red lead to the branch circuit red

lead and the oven black lead to the branch circuit
black lead in accordance with local codes, using

wire nuts.

5. Install proper strain relief clamp.

6. Installjunction box cover.

Range conduit

snaps into box

Branch

circuit

Alternate

knockout

White