Chamberlain SL 1000-X3 User Manual

Page 18

Advertising
background image

Rev J

Doc 01-20098

Page 18 of 44

K. BASIC GATE OPERATOR PROGRAMMING

Even if you plan to program the gate operator by telephone, you may want to enter some

immediate instructions during installation. The following list of instructions will help you set

basic controls so the gate will operate properly until you have time for full programming, either

directly or by telephone. For complete programming instructions, refer to the SL 1000, SW

2000, BG 3000 Programming Manual.

To access programming mode: enter ✱ ✱ ✱ 000000 (3 asterisks, 6 zeroes)

To program a command: a) enter step number b) enter required data c) enter # (pound sign)

To exit programming mode: enter 00# (2 zeroes, 1 pound sign)

Step

Purpose

# of

Digits

Default

Acceptable Input

01

Gate Type
(See Notes Below)

1

1

0 = Slide, 1 = Swing, 2 =

Barrier,

3 = Linear

02

Operator Type

1

0

0 = Single, 1 = Master, 2 =

Slave

03

Pair Type

1

0

0=Bipart, 1=Latch, 2=Not

Used, 3=Tandem

04

Not Used

-

-

-

05

Not Used

-

-

-

06

Anti-Tailgate Enable (ATG)

1

0

0 = Disabled, 1 = Enabled

07

Latch Delay Time

3

6

0 – 250 Seconds (.4 sec.

Increments)

08

Reclose Time (RT)

Up to 3

30

0 – 250 Seconds (0 =

Disabled)

09

Not Used

-

-

-

10

Not Used

-

-

-

11

Obstruction Sense Backup

Closing

Up to 3

12

2 – 499 Inches

12

Obstruction Sense Backup

Opening

Up to 3

12

2 – 499 Inches

13

Interrupt Bar Backup If Closing

Up to 3

12

2 – 499 Inches

14

Interrupt Bar Backup If Opening

Up to 3

12

2 – 499 Inches

15

Return to Factory Set Defaults

6

N/A

101010 (partial), 191919 (full)

NOTES:
1. If Gate Type is set to SLIDE, gate brakes whenever it stops.
2. If Gate Type is set to SWING, gate brakes only when it reaches the open or close limit.
1. If Gate Type is set to BARRIER or LINEAR, the gate never brakes.

Advertising