2. Start-Up

Sensitivity:

Apply a bump to the gate as it starts moving and verify that the gate responds to the bump within a
second.

3. Obstruction

Alarm:

Cause two obstruction faults before the gate reaches its open or closed limit and verify that the
Obstruction Alarm sounds.

5. Entry inputs

1. Activate the CYCLE input (entry system), RADIO input (radio transmitter), and EXIT Loop input
(driving over the exit loop) and verify that they fully open the gate. If Reclose Timer is enabled, it will
close the gate.

2. Activate the FIRE input (fire department switch) and verify that the gate fully opens and then
closes after 5 seconds. If Reclose Timer is enabled, it will close the gate.

6. Alternate Action

If Alternate Action has been selected so that CYCLE or RADIO commands both open and close the

gate:

Activate the CYCLE command, wait until the gate is fully open, then activate the CYCLE command

again. The gate should close, verifying Alternate Action operation.

Note: If you select Alternate Action, you can't enable ATG and RT in procedures 7 and 8.

7. Reclose Timer (RT)

If Reclose Timer has been enabled in programming step 8, verify Reclose Timer as follows:

1. Activate any entry command (except Manual OPEN) to open the gate.

2. Start timing when the gate reaches fully open and verify that the Reclose Timer recloses the gate
after the desired interval.

NOTE: Reclose Timer is not functional when the Manual OPEN command is used.

8. Inside Interrupt Loop and Anti-Tailgating (ATG) When Exiting

GATE TYPE is SLIDE

ATG OFF:

If ATG is turned OFF (0 entered in step 6), activate the CYCLE command, drive over the Interrupt Loop
and verify its operation:

#

Opening Gates: When a vehicle drives on the Interrupt Loop an opening gate will be

unaffected.

#

Closing Gates: When a vehicle drives on the Interrupt Loop a closing gate will open and the

Reclose Timer (if enabled) will start.

ATG ON: If ATG is turned ON (1 entered in step 6), activate the CYCLE command, drive over the
Interrupt Loop and verify its operation:

#

Opening Gates: When a vehicle drives on the Interrupt Loop an opening gate will continue to

open, but will close as soon as the vehicle drives off the Interrupt Loop.

#

Closing Gates: When a vehicle drives on the Interrupt Loop a closing gate will stop, but will

close as soon as the vehicle drives off the Interrupt Loop.