The LiftMaster Gate Operator Model SL 1000-X3

The LiftMaster model SL 1000-X3 Slide Gate Operator is a full-featured, commercial gate operator with

master/slave wiring capability. The SL1000-X3 contains the following features:

Satisfies U.L. 325 requirements for primary (motor current) and secondary (photo) obstruction

senses.
Five different open inputs are available for a variety of devices.
Dynamic motor braking limits gate overtravel.
Alternate action OPEN/CLOSE inputs.
Manual Open/Close/Stop inputs are provided for three button station.
Programmable Reclose timer.
Gate lock relay can be used for electromagnetic locks and CCTV cameras or lights.
Interrupt Bar input is included for use with edge sensors.
Master-Slave operation for two operators on bi-part gates and tandem gates.
Selectable anti-tailgate function prevents two cars from entering on one open command.
Open motor detection in case of motor thermal overload.
Maximum Run Time feature stops run-away motor in case of belt breakage.
Senses obstructions through adjustable Peak motor current sense and fixed average motor current

sense.
Two separate peak motor current sense adjustments for reversing direction or stopping; one for

left motion and the other for right motion.
Start-up current sense adjustment offsets initial inrush current to the motor.
Obstruction Alarm sounds the second time the gate is obstructed.
Cycle counter is able to initiate a service request call at a predetermined number.
Event recording memory keeps track of all commands and actions even during power interruptions.

This is very helpful in troubleshooting the system. Can be retrieved by modem into your computer.
Automatic service request call is activated in the event of a fault or warning condition. A call can be

made to any telephone or pager and will include system ID number and fault condition code.
12-button keypad and 7-segment display to facilitate programming, service and operation.
Automatic OPEN/CLOSE and Alert Call schedules include holidays.
Two 115 VAC accessory plugs provided.
24 VAC accessory power provided.
Diagnostic LEDs on controller board indicate gate operator actions and assist in troubleshooting.
Telephone interface permitting remote gate operator programming and diagnostics.
Inside and outside Interrupt Loops and Photo-Sensors inputs enhance gate control and

distinguish between entering and exiting traffic.
True

½

" HP high starting torque motor reduces stalling.

A 30:1 gearbox is used to prevent gate from being pushed open.
Controls any gate travel distance up to 45 feet.
Handles any gate weight up to 1000 pounds.
Standard size 40 chain is provided.
Internal quick disconnect system provides fast gate-chain disengagement.
Optional loop detector add-on boards plug into the controller board, reducing wiring.
DIMENSIONS WEIGHT

ELECTRICAL

Height 25

½

"

107 lbs.

115 VAC, Single Phase, 60 Hz., 15 amp

Width 15"

(A separate 20 AMP circuit is

Depth 21"

required by most codes.)