ELECTRICAL
All wiring must be in accordance with eiectrica! codes The dishwasher operates on 115 volt, 60 cycle power Pro
vide a separate circuit with a fuse or circuit breaker rated lor at least 15 amps but not more than 20 amps
GROUNDING INSTRUCTIONS
This appliance must be connected to a grounded metal, permanent, wiring system: or an equipment grounding
conductor must be run with the circuit conductors and connected to the equipmenTgrounding terminal A green 
ground screw terminal is provided in the junction box Connecting the circuit conductor ground, along with the 
molded receptacle green pigtail, automatically grounds the dishwasher
install the wiring, routing it within the zones shown in Figure 5, Do not run it across in front of the motor Connect 
the circuit black lo the machine black, and circuit white to the machine white, using wire nuts If house wiring is 
aluminum, a UL or CSA listed antioxidant compound must be used with listed aluminum-to-copper connectors 
Connect the circuit conductor ground wire under the green ground screw Refer to Figure 6 Replace the junction 
box cover '
CONDUCTOR GROUND WJRE
GREHN GROUND
S C R E W
FIGURE 6