PROBLEM
POSSIBLE CAUSE
ACTION
Dishes not clean.
Dishwasher will not
operate when turned on..
Dishwasher
automatically
repeats with door latched
Dishwasher runs with 
door open
1.
No power to dishwasher.
2 Open circuit between power source
and timer
3-, Loose terminal connections at door
switch arrd/or timer terminals,
4.
Defective door switch
5.
Defective selector switch.
6.
Defective timer motor circuits.
7
Defective start switch.
8. Main motor defective.
1,
Start switch contacts sticking ciosed.
2- A grounded timer motor combined with
reverse polarity connection at junction 
box Of wall receptacle causing the "hot" 
side of the circuit to bypass "off 
switches in the timer.
3,
Grounded thermostat with reverse
polarity
4,
Broken slides inside of selector switch 
(rapid advance timer only).
1.
Door switch defective.
2.
Terminals shorted to each other at the
door switch,
3.
Latching handle turned to the "ON"
position.
Grounded elsctricsl component 
combined with reverse polarity 
connection at function box or wall 
receptacle.
Refer to introductory section at 
beginrtlng of this manual,
1.
Check electrical outlet or connection
to junction box on built-in,
2 Check wiring and/or povs'er cords,.
3.
Repair as needed,
4.
Check continuity.
B„ Check continuity,
6. Refer to Timer Testing.
Applies to models with a rapid advance
timer. Check continuity.
8. Refer
to Motor Testing.
1„ Repiace start switch.
2,
Repiace timer, Refer to installation 
Instructions for proper Blectricai 
connection and grounding of power
receptacles.
3,
Replace thermostat. Check electrical
connection
4,
Refer to wiriftg diagram and check 
selector switch circuitry.
1. Check continuity.
2.
Repiace defective parts.
3.
Check safety tab, which prevents 
turning handle Into run position with 
door open.
4.
Replace defective component. Refer 
to Installation Instruction for proper 
electrical connection and grounding 
of power receptacle.