Figure 14 – Kenmore 808353 User Manual

Page 20

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

NORMAL CHARGE-

FLOAT

SWITCH

FIGURE 14

2 Testing Water Charge Level

To check for orooer water level, pour the minimum charge of 8 quarts of water into the tub and make a reference
mark with a grease pencil or crayon at the edge of the waterline Then pour in an additional 1 A quarls of water
to make the maximum charge, and make another reference line at the edge of the water line. Set the timer to a
portion of the, operating cycle for "drain" and allow the drain pump to pump out the water Allow the tirne to ad­
vance into a '"’fiir' period of the operating cycle and allow the norma! amount of water to im the tub Alter the
water inlet valve has shut off, compare the edge of the water line with the reference marks made above The water
charge must be between the two lines Remove ihe marks after completing this test i he water level snouio cover

the healing element

17

Advertising