Table 7.1: Summary Of Horizontal Venting Options

VENT OPTION #

1

2

3

4

CLASSIFICATION USED IN THIS

MANUAL

HORIZONTAL

CONCENTRIC

HORIZONTAL

CONCENTRIC

HORIZONTAL

CONCENTRIC

RESERVED

FOR FUTURE

USE

ILLUSTRATED IN FIGURE

7.2

7.2

7.2

VENT PIPE PENETRATION

THROUGH STRUCTURE

WALL

WALL

WALL

VENT PIPE SIZE

60/100 mm

CONCENTRIC

60/100 mm

CONCENTRIC

80/125 mm

CONCENTRIC

INLET AIR ORIFICE SIZE

82mm

Not Used

82mm

MAX. VENT LENGTH

25in

8ft - 10in

27ft - 10in

MIN. VENT LENGTH

6in

26in

6in

VENT TERMINAL

CROWN

#230520

(INCLUDED

WITH BOILER)

CROWN

#230520

(INCLUDED

WITH BOILER)

CROWN

#230531

VENT MATERIAL

CROWN

60/100mm

VENT

COMPO-

NENTS

SHOWN IN

TABLE 7.3a

CROWN

60/100mm

VENT

COMPO-

NENTS

SHOWN IN

TABLE 7.3a

CROWN

80/125mm VENT

COMPONENTS

SHOWN IN

TABLE 7.3b

Figure 7.2: Horizontal Concentric Venting (Vent Options 1-3)