4. ADDITIONAL FUNCTION KEYS AND REGISTERING

PROCEDURE

The following are keys that can be installed on a MA-1900 ECR of Master or Satellite specifications,
in addition to the stand-alone specifications, and the registering procedure using each of the keys.

PLU

ADD

PLU ADD KEY ([PLU ADD])

This key is used to add the table of an unprogrammed PLU item (Manual Entry

PLU or Barcode Label Item) to the PLU program file memory of the ECR.

The PLU can be entered by first depressing this key, next entering the PLU Code

(or by scanning the barcode), and then entering the link Department Code and the

preset price. The PLU entered in this way can be entered normally from the next

time on.

REGISTERING PROCEDURE FOR AN URGENT PLU TABLE ADDITION

This operation is effective when an “E04” error (undefined code) occurs on entering a PLU
code or scanning a barcode of an item in the ordinary entry procedure. The error means
that the PLU code has not been programmed in the PLU file. By operating the following

procedure, the PLU is entered as a sale item, and at the same time, it is programmed as an

additional PLU so that it can be entered as an ordinary PLU thereafter.

Mode Lock: REG, MGR, or El / GT Lock: Neutral (operable on Master or Satellite ECRs)

ex.)

[PLU ADD]

-► ( |Quantitv|

[X]

)

in case of quantity extension

|PLU Code|

[PLU]

Or, scan the barcode.

[DEPT]

—► |Dept Code]

[DP#]

Link Department Designation

|Price|

[AMT]

(NOTE:

[X] = [@/FOR] ;

An operator attempts to enter 4 items of PLU Code 1234 at unit price $2.00 (linked to

Department 3) during a sale, but an '*E04” error results. Therefore, the following is
operated to enter and program this PLU item.

Mode Lock & GT Lock positions: same as preceding item entries.

[PLU ADD]

(to declare an additional PLU entry and programming)

4 [ X ]

(to enter the quantity "4")

12345

[PLU]

(to enter the PLU Code; can be replaced by scanning the barcode)

3

[DP#1

(to enter the Link Department Code)

200 [AMT] (to enter the unit price of the item)

- 4 -