7 alibi memory and legal metrological records, Alibi memory and legal metrological records, Alibi data connector – Flintec FT-16D V.1.21 User Manual

Page 17: ] metrological data block, ] legal metrological records

Advertising
background image

7 A

LIBI

M

EMORY AND

L

EGAL

M

ETROLOGICAL

R

ECORDS

If the alibi memory is installed and activated, the indicator keeps the latest 149 764 weighing records in this
memory. The recorded data can be viewed on the indicator’s display or exported via serial port.
To find a definite record you have to enter parameter [802]. After reaching the desired record, the recorded data
can be viewed in the display. If needed you can print this record together with the following 9 records by
pressing the <Print> key. If you press the <Print> key in parameter [803], all recorded data will be sent via serial
port. The <F> key cancels the print job.
Empty fields will be printed as “------“ , corrupted records as “xxxxx” . For the records for which weighing
results cannot be given, the message “no rec” will be shown on the display.
If the alibi memory is activated, the alibi record number is also found on the print out data.
After installing the alibi board or changing the main board “Error 41” or “Error 42” will be shown on the display
after power on because the activation of the alibi memory is required.
If the calibration jumper is short circuited, you can activate the alibi board by pressing the <Enter> key after
power on. Otherwise the alibi errors will disappear by pressing the <Enter> key, but you cannot export any data
(Error “43” will be shown after pressing the <Print> key ).

Alibi data connector:

The alibi data connector must be used for printing the alibi records. This connector (D-Sub, 9 pin, female) is
located inside the housing.

Alibi connector within FT-16(D)

Pin no. (D-Sub, 9-pin, male)

Definition

3 TXD
5 GND

Baud rate: 9600; 1 start bit, 8 data

bits, 1 stop bit and no parity bit

[8--] Metrological Data Block

The parameters about Metrological Registry are being entered in this section.

[80-] Legal Metrological Records

In this block edit the parameters with <

↑> key and use the <Enter> key according to the parameter’s

description.

[800] Counter

This counter increases automatically by 1 after starting the setup mode with enabled calibration jumper
and service password. This counter cannot be changed manually.

[801] Alibi

Memory)

0 = Disabled

1 = Enabled

[802]

Finding any record from Alibi Memory

You can call any record from the Alibi Memory by <Tare> and <Zero> keys. If the <Print> key is pressed
while an alibi record is on the display, this and the 9 previous records will be printed.

[803]

Print all Alibi Memory records

All data from the Alibi Memory can be printed by pressing the <Print> key. You can stop printing with the
<F> key.

[804] Alibi

Info

You can get some basic information about the alibi memory board and the records by pressing the
<Print> key. These data are:

• SN

: Pin code of the alibi memory card

• SA

: The alibi record start number within this indicator

• LA

: The alibi record number of the next weighing with this indicator

• CN : Calibration counter number

• CS : Check sum status

• AS : Capacity of the alibi memory

FT-16(D) Technical Manual, Rev. 1.21 December 2008

Page 17 of 32

Advertising
This manual is related to the following products: