GTCO Summagrid VII - Users Guide User Manual

Page 24

Advertising
background image

Summagrid VII 24

4. The cursor turns on again at the new frequency. You will know the cursor is on

when the Indicator Light glows steadily.

To return to the default frequency, repeat the above process. When you replace the cursor
batteries, the cursor is automatically reset to the default frequency.

Changing the Frequency of the Cordless Pen

Press both side buttons and the tip simultaneously and hold for approximately three
seconds. To return to the default frequency, repeat the above process. When you replace
the pen batteries, the pen resets to the default frequency.

Changing the Frequency of a Corded Transducer

You must use the Menu Strip to change the frequency of the corded transducers (see the
Setting corded frequency option in the Tablet Options section).

Tablet Checklist

Is the tablet power supply (used only with the serial connection to the computer)
plugged into the digitizer and into a live outlet?

Is the tablet power switch on?

Does the Indicator Light glow steadily when the transducer is in prox inside the
Active Area? Does the Indicator LED go out when the transducer is outside the
Active Area?

The Indicator Light will be off if the transducer has gone into Sleep Mode. Press any
button on the transducer to activate it. If the transducer is in the Active Area and
the Indicator Light remains off, change the transducer’s battery.

Are all cable connections seated properly?

Is the communications cable (either USB or serial) connected to both the digitizer
and the computer? Check that the cable is connected to the serial port specified in
your software package.

Is the transducer cable connected to the digitizer?

Is the tablet set up according to the software recommendations?

Are any of the connector cables or receptacles damaged? Check for bent pins, cut
insulation and loose wires.