Typical applications – Haltech F10 User Manual

Page 37

Advertising
background image


32

Switch 3 – Pull to Ground

This switch adds a 4.7kΩ pull to ground opposing the Pull-Up 2 resistor.


Switch 4 – Filter Capacitor 1

This switch adds a 0.1uF filter capacitor to the input of the trigger circuit.


Switch 5 – Filter Capacitor 2

This switch adds a 0.001uF filter capacitor to the input of the trigger circuit after series
impedance.


Switch 6 – Resistor Bypass

This switch applies a short circuit across a 4.7kΩ series resistance on the input of the

trigger circuit.


Switch 7 – Input Impedance

This switch allows the user to set the input protection impedance to either low ore
high. High is used in coil negative applications where low is used for Hall Effect or

optical digital trigger applications.


Switch 8 – Input Threshold

This switch controls the threshold voltage at which the trigger circuit will switch state.

Typical Applications

Software Switches

Trigger Type

1 2 3 4 5 6 7 8

Haltech S1/S3,S2/S4 Hall

Effect Sensor

2

2

2

2

3

3

3

3

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

LOW 3.4V

Ignition Coil Negative

terminal

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

HIGH 3.4V

Driven 12V square wave

(some tacho output

signals)

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

3

HIGH 3.4V

3

3

3

3

= On 2

2

2

2

= Off

Advertising