20

NOVUS FP – REPLACING THE FLYBAR

Loosen the screws on both flybar paddle collars. Rotate the paddles counter
clockwise to remove the paddle and the collar from the flybar. Loosen the screws on

the flybar carrier (both sides). At
this point the flybar can be slid
out of the flybar carrier. Slide
the new flybar into the flybar
carrier and ensure that the
new flybar is centered. Tighten
the flybar carrier screws and
reinstall the paddles. Ensure
that the paddles are equal
distances out on the flybar and
tighten the flybar paddle collar
screws.

NOVUS FP – REPLACING THE MAIN GEAR

Remove the lower retaining
pin from the main gear using
needle nose pliers. Remove
the old main gear from the
model and install the new main
gear. Align the hole in the main
shaft with the hole in the main
gear and press the small pin
back through the hole.

NOVUS FP – REPLACING THE MAINSHAFT

Remove the lower retaining
pin from the main gear
using needle nose pliers.
Disconnect the servo linkages
from the swashplate. Slide the
main shaft straight up and out
of the main frame. Remove
and transfer necessary parts
to the new main shaft and
reinstall by reversing the
order listed above.