IC Realtime 4 Channel PoE Mobile Network Video Recorder User Manual
Page 132
 
123
Parameter Function
Normal 
Out 
The corresponding alarm output channel when an alarm occurs.
Latch
The alarm output can delay for the specified time after alarm stops. The 
value ranges from 10s to 300s. 
Record 
channel 
After you selected the disk connection option, once the device is offline, 
the activated channel can begin alarm record. 
Record 
latch 
System can delay the record for specified time after alarm ended. The 
value ranges from 10s to 300s. 
SMS
If you check the box here, system can send out a message to the 
specified mobile phone when an alarm occurred. 
Send 
email 
If you enable this function, system can send out email to alarm the 
specified user. 
Show 
message 
Once you check the box to enable this function, system can display the 
alarm icon on the right of the channel name at the local end. 
6.4.3.3 Alarm I/O
Here you can search alarm output status. See Figure 6-48.
Figure 6-48 Alarm I/O Configuration
Important
The alarm output port should not be connected to high power load directly (It shall be less than 1A)
to avoid high current which may result in relay damage. Please use the co contactor to realize the
connection between the alarm output port and the load.
Please refer to the following sheet for detailed information.