Table 5: Zone types

Zone type

Description

Zone type

Description

1. Day zone

This zone is instant when the system is armed;
trouble zone when the system is disarmed.

2. 24-hour
audible.

This zone creates an instant yelping siren alarm
regardless of the armed state of the control panel.

3. Entry/exit
delay 1

ing exit

or instant mode if

A trip starts entry delay 1. The lack of a trip dur
delay enables the automatic bypass
programmed.

4. Follower with

d no

autobypass
disabled

This zone is instant when the system is armed an
entry or exit delays are being timed. It is delayed 1
time during entry and exit. This zone does not
automatically bypass even if enabled in segment 1.

5. Interior
follower with
autobypass

This zone is instant when the system is armed and no
entry or exit delay is being timed. It is delayed 1 time
during entry and exit. This zone automatically
bypasses if enabled in segment 1.

6. Instant

This zone creates an instant alarm whenever it is
tripped and the armed LED is on.

7. 24-hour

es an instant silent alarm regardless

silent

This zone creat
of the armed state of the control panel. It does not
display on the keypad.

8. Fire

This zone illuminates the fire LED and sounds the

ach time the zone is shorted. The fire

ED flashes rapidly indicating a problem if the zone is

temporal siren e
L
open.

9. Entry/exit
delay 2

A trip starts entry delay 2. The lack of a trip during exit
delay enables the automatic bypass or instant mode if
programmed.

10. 24-hours

on

silent
supervised

This zone creates an instant silent alarm regardless
of the armed state of the control panel. It displays
the keypad.

11. Reserved

12. Interior

ant when the system is armed and no

being

follower with
cross zone

This zone is inst
entry or exit delay is being timed. It is delayed during
entry and exit delay times. If a

cross zone

is not being

timed, it starts a

cross zone

timer. If a

cross zone

is

timed, it creates an instant alarm. This zone
automatically bypasses when enabled in segment 1.

13. Instant
entry guard

lay

This zone creates on instant alarm whenever it is
tripped and the stay LED is off. It starts an entry de
type 2 if it is tripped, the system is armed, and the
stay LED is on.

14. Entry/exit

y delay 1. This zone bypasses when

ad.

delay 1 with
group bypass

A trip starts entr
the group bypass command is entered at the keyp
The lack of a trip during exit delay enables the
automatic bypass or instant mode if programmed.

15. Interior

ant when the system is armed and no

ypasses if enabled

follower with
group bypass

This zone is inst
entry or exit delays are being timed. It is delayed
during entry/exit delay times. This zone bypasses
when the group bypass command is entered at the
keypad. This zone automatically b
in segment 1.

16. Instant with
group bypass

17. Entry/exit
delay 1 with
tamper

exit

if

A trip starts entry delay 1. The lack of a trip during
delay enables the automatic bypass or instant mode
programmed. This zone type is used to enable the
tamper on a wireless transmitter.

18. Interior
follower with
tamper and

g

ne automatically

autobypass

This zone is instant when the system is armed and no
entry or exit delay is being timed. It is delayed durin
entry and exit delay times. This zo
bypasses if enabled in segment 1. This zone type is
used to enable the tamper on a wireless transmitter.

19. Instant with

er it is

tamper

This zone creates an instant alarm whenev
tripped and the armed LED is on. This zone type is
used to enable the tamper on a wireless transmitter.

20. Entry/exit

ith

ng exit

delay 2 w
tamper

A trip starts entry delay 2. The lack of a trip duri
delay enables the automatic bypass or instant mode if
programmed. This zone type is used to enable the
tamper on a wireless transmitter.

21. Gas
detection

This zone creates an instant alarm regardless of the
armed state of the control panel. It displays on the
keypad and activates the keypad sounder

22. Low

n instant silent alarm regardless

temperature
detection

This zone creates a
of the armed state of the control panel. It displays on
the keypad and activates the keypad sounder.

23. High

ess

temperature
detection

This zone creates an instant silent alarm regardl
of the armed state of the control panel. It displays on
the keypad and activates the keypad sounder.

24. Manual fire

the

shorted. It also

This zone illuminates the fire LED and sounds
temporal siren each time the zone is
flashes (rapidly) the fire LED, indicating a problem if
the zone is open.

25. Chime only

rmed

anytime it is

This zone creates no alarm regardless of the a
state of the control panel. It chimes
faulted and displays on the keypad. Local only.

26. Interior
follower delay 2

lay is being timed. It is delayed 2 times

This zone is instant when the system is armed and no
entry or exit de
during entry and exit. This zone automatically
bypasses if enabled in segment 1.

27. Inter
follower force

ior

armable

e

nabled in segment 1.

This zone is instant when the system is armed and no
entry or exit delay is being timed. It is delayed 1 tim
during entry and exit. This zone automatically
bypasses if e

28. Entry/exit
force armabl
delay 2

e

A trip starts entry delay 2. The lack of a trip during exit
delay enables the automatic bypass or instant mode if
programmed.

29. Interior

d no

during

f the

abled in

follower with
activity
supervision

entry or exit delay is being timed. It is delayed
entry and exit delay times. It sends a report i
zone activity time is reached without a change of

This zone is instant when the system is armed an

state. This zone automatically bypasses if en
segment 1:

30. Entry/exit

A trip sta

ne

time is reached

The

tic

bypass o

with activity
supervision

activity
lack of a

rts entry delay 1. It sends a report if the zo

without a change of state.

trip during exit delay enables the automa
r instant mode if programmed.

Underwriters lab

s

This zone creates an instant alarm whenever it is
tripped and the armed LED is on. This zone bypasse
when the group bypass command is entered at the
keypad.

o

formation

The NetworX NX-4V2 holds the following listings from

Underwriters Laboratories (US and Canadian):

ratories in

6

NX-4V2 Control Panel Installation Instructions