9

e

electable 50 mS or 500 mS

Loop respons

S

Operating temperature

to 49°C)

32 to 120°F (0

LED keypad

Current draw

/o

30 mA max.

in. (16.3 x 10.2 x 2.8 cm)

Zones normal w
sounder

Dimensions

1

55 mA


6.4 x 4.0 x 1.1

NX148E LCD keypad

er

x 1.0 in. (16.3 x 13.5 x 2.5 cm)

Current draw

Without sound

Dimensions

110 mA max.

75 mA

6.4 x 5.3

Metal enclosure
dimension

x 3.50 in. (28.58 x 28.58 x 8.90

cm)

11.25 x 11.25

Shipping weight

9 lb. (4.1 kg)

Regulatory information

FCC compliance

This device complies with part 15 of the FCC
rules. Operation is subject to the following
conditions:

This device may not cause harmful interference.

This device must accept any interference
received, including interference that may cause
undesired operation.

Changes or modifications not expressly approved
by the party responsible for compliance could
void the user’s authority to operate the
equipment.

Complies with Part 68 FCC Rules.

ACTA (FCC) ID: GCQUSA-33408-AL-E

IC: 1175A-NXV2

Contact information

For contact information, see www.utcfireandsecurity.com or

www.interlogix.com.

For technical support, toll-free: 888.437.3287 in the US

including Alaska, Hawaii, Puerto Rico, and Canada. Outside

the tool-free area, contact your dealer.

Copyright © 2011 UTC Fire & Security. All rights reserved.

ANSI/SIA CP-01 requirements

CP-01 feature descriptions and specifications are listed in Table 7 below. The following are requirements for compliance with

ANSI/SIA CP-01 standards.

Note: Where a conflict exists, UL requirements take precedence over ANSI/SIA requirements.

Minimum system requirements:

One control panel

• • Two

keypads

Do not enable remote arming in SIA classified installations.

Off premise transmission must be in the SIA format.

Do not exceed 1 minute for the abort window and entry delay.

Note: A call-waiting cancel on a noncall-waiting line prevents successful connection to the central station.

Table 7: CP-01 feature descriptions and specifications

CP-O1 feature description

Feature description as shown in
manual

Program
location

Seg/opt Default

CP-01required

setting

Exit 1 delay

24

2

60

45 to 240 seconds

Exit time

Exit 2 delay

24

4

60

45 to 240 seconds

Progress annunciation /
disable - for silent exit

Silent keypad option

93

a

2

All annunciators enabled Allowed (individual

keypads may be disabled)

Exit time restart (reexit)

This feature is not programmable in the panel.

Enabled

Auto stay arm on unvacated
premises

Auto bypass

23

1/3

Enabled

Enabled