© 2006 Jaypro Sports Equipment JSL-Inst002 Rev F3 9-1-2006

6 of 14

c. Run high voltage wiring from winches into control panel. Hook up to motor starters.

See note below about phasing of motors. Be sure to connect ground wires from hoists
into control panel terminal.

Figure 7: Motor Starters

d. Change setting for motor starter overloads according to voltage present. Turn blue dial

with a small screwdriver to adjust.

Figure 8: Overload Setting

Voltage Setting

440, 460, 480

3.7

220, 230, 240

7.1

200, 208

7.7

Table 2: Overload Settings