Chapter 4 Troubleshooting the Installation

Troubleshooting an AC Power Subsystem

4-8

Cisco XR 12406 Router Installation Guide

OL-13831-01

Step 2

Check the AC power source.

•

Check the AC power cord from the power source to the router.

–

Verify that the power cord is seated securely in the PDU and the AC
outlet.

–

Verify that the power cord is not worn or damaged. If the insulation
appears cracked or broken, or the plugs appear loose, replace the power
cord with a new power cord.

•

Make sure that the AC power source circuit breaker is on and has not tripped,
and that the circuit breaker has the proper current rating.

•

Verify that each power supply in the router is attached to a separate AC power
source.

•

If the router is connected to an uninterruptable power supply (UPS), verify
that the UPS is functioning correctly.

Note

There may be a UPS for each power supply in the system.

If the AC power source appears to be okay, but the power supply AC LED remains
off, go to Step

3

.

Step 3

Plug the power cord into a different, but compatible AC outlet.

•

If the power supply AC LED goes on, the original AC outlet is faulty and
cannot be used. Notify the appropriate facilities personnel and go to Step

6

.

•

If the power supply AC LED remains off, go to Step

4

.

Step 4

Exchange the existing power cord for another power cord.

•

If the power supply AC LED goes on, the original power cord is faulty and
must be replaced. After replacing the power cord, go to Step

6

.

•

If the AC LED still fails to go on when connected to a different power source
with a new power cord, the power supply is probably faulty. Go to Step

5

.

Step 5

If a spare power supply is available, replace the existing module with the spare
and restart the system.

•

If the AC LED on the spare power supply goes on, the original power supply
is faulty and should be returned for replacement. Go to Step

6

.