Ok led goes on, go to step – Cisco XR 12406 User Manual

Page 142

Advertising
background image

Chapter 4 Troubleshooting the Installation

Troubleshooting a DC Power Subsystem

4-12

Cisco XR 12406 Router Installation Guide

OL-13831-01

Step 4

Power off the PEM circuit breaker switch and check the DC power source.

•

Check the DC power wires from the power source to the router.

–

Verify that the power wires are fastened securely at the PDU and the DC
source.

–

Verify that the power wires are not worn or damaged. If the insulation
appears cracked or broken, have the power wires replaced.

•

Make sure that the DC power source circuit breaker is on, and that it has the
proper current rating.

•

Verify that each PEM in the router is attached to a separate DC power source.

•

Power on the PEM circuit breaker.

–

If the PEM INPUT OK LED goes on, go to Step

6

.

–

If the PEM INPUT OK LED remains, go to Step

5

.

Step 5

Remove the PEM and insert it in the second bay in the router, or into a bay on
another Cisco XR 12406 router.

•

If the INPUT OK LED remains off, the PEM is faulty and needs to be
replaced.

•

If the INPUT OK LED goes on, the input portion of the PEM is working
normally, go to Step

6

.

Step 6

Is the OUTPUT OK LED on?

•

If yes, the power source is good and the PEM is operating normally.

•

If no, and there is no other system activity (blower module is off; line cards
are unpowered), the PEM is fault. Replace the PEM.

•

If no, but the blower module is operating, it means all internal DC voltages
are within tolerance. Suspect a faulty OUTPUT OK LED.

–

Use the show environment command to check the voltages on each card.
The blower module uses –48 VDC.

Note

In a Cisco XR 12406 router with two power supplies, the output power
from the second power supply is adequate to maintain router operation.