2 between entraguard network and host computer, 1 phone line (internal modem), Entraguard – Keri Systems EntraGuard Platinum Quick Start User Manual

Page 14: Platinum telephone entry controller, Quick start guide

Advertising
background image

EntraGuard

®

Platinum Telephone Entry Controller

Quick Start Guide

Page 14 of 28

P/N: 01969-001 Rev. C

6.2

Between EntraGuard Network and Host Computer

A communication link between the EntraGuard network and the host computer is provided via one of two ways.

using the phone line connected to TB-15

using the RS-232 serial port

NOTE: In order for monitor mode to work, the RS-232 serial port method must be used (see Section 6.2.2 on page 15).

NOTE: If a PXL controller is connected to the EntraGuard, it may be used as the master controller for communication
which will free up the phone line. For further information on communication alternatives, see either the PXL-500/PXL-
510 Quick Start Guide (P/N 01918-001) or the PXL-500G-1 Quick Start Guide (P/N 01532-001).

6.2.1

Phone line (Internal Modem)

The EntraGuard Platinum controller’s internal modem may be used for communication between the master controller and

an external modem

1

connected to the host computer. To use the EntraGuard’s internal modem, attach the phone line to

TB-15 located on the master controller’s board (see Figure 2 on page 2).

NOTE: If you are using two separate phone lines, one for communication with the tenants and one for programming, you
will not be able to use the internal modem for programming and must use an external modem connected to the RS-232 as
described in Section 6.2.2.2 on page 17.

Once the phone line has been attached, the J11 jumper must be set for proper operation. When using TB-15 phone line
connection for communication with the host computer, place the jumper on the INT_MODEM jumper (see J11 on Figure
2 on page 2).

The Doors software must also be configured for using the internal modem. In the Doors software, click on the

button, then select the Network Config tab. In the “Modem Init String” field type in AT&K0

2

(see Figure 16). Click on

the

button.

Figure 16: Modem Init String Set

NOTE: For wiring of an external modem to the host computer, see Section 6.2.3 on page 19.

1. You must use a Keri Systems modem for proper communication.
2. Although it is not necessary to enter this code with every type of modem, Keri Systems recommends you

enter it in all situations for proper communication between the master controller and the host computer.

Advertising